The 20-minute whole blood clotting test (20WBCT) for snakebite coagulopathy—A systematic review and meta-analysis of diagnostic test accuracy

Thomas Lamb, Michael Abouyannis, Sâmella Silva de Oliveira, Shenoy K. Rachana, Tulasi Geevar, Anand Zachariah, Sanjib Kumar Sharma, Navin Bhatt, Mavuto Mukaka, Eli Harriss, David Lalloo, Elizabeth A. Ashley, Wuelton Marcelo Monteiro, Frank Smithuisid, Michael Eddleston

Research output: Contribution to journalArticlepeer-review

38 Citations (Scopus)

Abstract

Background

The 20-minute whole blood clotting test (20WBCT) has been used to detect coagulopathy following snakebite for almost 50 years. A systematic review and meta-analysis of the 20WBCT was conducted to evaluate the accuracy of the 20WBCT to detect coagulopathy, indicative of systemic envenoming.

Methods and findings

Databases were searched from inception up to 09/12/2020 to identify studies that compared the 20WBCT and INR/fibrinogen on five or more subjects. Data was extracted from full-text articles by two reviewers using a predetermined form. Authors of 29 studies that lacked sufficient details in the manuscript were contacted and included if data meeting the inclusion criteria were provided. Included studies were evaluated for bias using a tailored QUADAS-2 checklist. The study protocol was prospectively registered on PROSPERO database (CRD42020168953).

The searches identified 3,599 studies, 15 met the inclusion criteria and 12 were included in the meta-analysis. Data was reported from 6 countries and included a total of 2,270 patients. The aggregate weighted sensitivity of the 20WBCT at detecting INR >1.4 was 0.84 (CI 0.61 to 0.94), the specificity was 0.91 (0.76 to 0.97) and the SROC AUC was 0.94 (CI 0.91 to 0.96). The aggregate weighted sensitivity of the 20WBCT at detecting fibrinogen <100 mg/dL was 0.72 (CI 0.58 to 0.83), the specificity was 0.94 (CI 0.88 to 0.98) and the SROC AUC was 0.93 (0.91 to 0.95). Both analyses that used INR and fibrinogen as the reference test displayed considerable heterogeneity.

Conclusions

In the absence of laboratory clotting assays, the 20WBCT remains a highly specific and fairly sensitive bedside test at detecting coagulopathy following snakebite. However, clinicians should be aware of the importance of operator training, standardized equipment and the lower sensitivity of the 20WBCT at detecting mild coagulopathy and resolution of coagulopathy following antivenom.

Original languageEnglish
Article numbere0009657
Pages (from-to)e0009657
JournalPLoS Neglected Tropical Diseases
Volume15
Issue number8
DOIs
Publication statusPublished - 10 Aug 2021

Fingerprint

Dive into the research topics of 'The 20-minute whole blood clotting test (20WBCT) for snakebite coagulopathy—A systematic review and meta-analysis of diagnostic test accuracy'. Together they form a unique fingerprint.

Cite this