Skip to main navigation Skip to search Skip to main content

Simultaneous Denoising and Reconstruction of 12-Lead Electrocardiogram

  • University of Leicester

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

4 Citations (Scopus)

Abstract

Promising results have been shown in previous studies for the reconstruction of 12-lead electrocardiogram (ECG) using machine learning techniques. Reliable results have also been shown for denoising ECG with machine learning tools. These two tasks (denoising and reconstruction) are typically handled separately, but this does not have to be. This paper aims to construct 5 denoised ECG leads from a subset of 3 noisy ECG leads. It also aims to analyse the performance of the models over 5 different noise levels. 30s ECG signals were acquired from 80 patients in PTB database. They were denoised and resampled to 500Hz. Different levels of gaussian noise (OdB, 5dB, 10dB, 15dB, 20dB) were added to lead I, II and V3. Linear regression (LR) and long short-term memory (LSTM) models were trained at the different noise levels to predict denoised leads V1, V2, V4, V5, and V6. 80% of the data was used to train the model and 20% was used to test. The average values of Pearson correlation (r), root-mean-square error (RMSE) and signal-to-noise ratio (SNR) against the baseline at Odb were 0.79±0.12, 0.12±0.05mV, and 4.26±2.41dB for LR and 0.87±0.15, 0.10±0.05mV, and 6.42±3.34dB for LSTM respectively. At 20dB they were 0.91±0.10, 0.08±0.05mV, and 7.73±3.99dB respectively for both models. Both models showed similar performance in higher input SNR. As the input SNR reduced, LSTM model showed a more stable performance. At higher input SNR, LR is recommended, whereas at lower input SNR, LSTM is the better option.

Original languageEnglish
Title of host publicationProceedings - 2024 International Symposium on Electrical, Electronics and Information Engineering (ISEEIE)
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages298-303
Number of pages6
ISBN (Electronic)9798350355772
DOIs
Publication statusPublished - 1 Aug 2024
Externally publishedYes
Event4th International Symposium on Electrical, Electronics and Information Engineering, ISEEIE 2024 - Leicester, United Kingdom
Duration: 28 Aug 2024 → 30 Aug 2024

Publication series

NameProceedings - 2024 International Symposium on Electrical, Electronics and Information Engineering, ISEEIE 2024

Conference

Conference4th International Symposium on Electrical, Electronics and Information Engineering, ISEEIE 2024
Country/TerritoryUnited Kingdom
CityLeicester
Period28/08/24 → 30/08/24

Keywords

  • denoising
  • electrocardiogram
  • LSTM
  • reconstruction
  • regression

Fingerprint

Dive into the research topics of 'Simultaneous Denoising and Reconstruction of 12-Lead Electrocardiogram'. Together they form a unique fingerprint.

Cite this