Multiplex loop-mediated isothermal amplification (multi-LAMP) assay for rapid detection of mcr-1 to mcr-5 in colistin-resistant bacteria

Lan Lan Zhong, Qian Zhou, Cui Yan Tan, Adam Roberts, Mohamed Abd El Gawad El-Sayed Ahmed, Guanping Chen, Min Dai, Fan Yang, Yong Xia, Kang Liao, Yingjian Liang, Yongqiang Yang, Siyuan Feng, Xiaobin Zheng, Guo Bao Tian

Research output: Contribution to journalArticlepeer-review

44 Citations (Scopus)

Abstract

Purpose:

The discovery of the plasmid-mediated colistin resistancegenes, mcr,revealed a mechanism of transmission of colistin resistance, which is a major, globalpublic health concern especially among individuals infected with carbapenem-resistant Gram-negative bacteria. To monitor the spread and epidemiology of mcr genes, a convenient and reliable method to detect mcr genes in clinical isolates is needed, especially in the primary care institutions. This study aimed to establish a restriction endonuclease-based multiplex loop-mediated isothermal amplification (multi-LAMP) assay to detect mcr genes (mcr-1 to mcr-5) harbored by colistin-resistant bacteria.

Methods:

A triple-LAMP assay for mcr-1, mcr-3, and mcr-4 and a double-LAMP assay for mcr-2and mcr-5 were established. The sensitivity and specificity of the LAMP reactions were determined via electrophoresis and visual detection.

Results:

The sensitivity of the LAMP assay was 10-fold greater than that of PCR, with high specificity among the screened primers. Specific mcr genes were distinguished in accordance with band numbers and the fragment length of the digested LAMP amplification products. Furthermore, the LAMP assay was confirmed as a rapid and reliable diagnostic technique upon application for clinical samples, and the results were consistent with those of conventional PCR assay.

Conclusion:

The multi-LAMP assay is a potentially promising method to detect mcr genes and will, if implemented,help prevent infections by drug-resistant bacteria in primary-care hospitals due to rapid and reliable surveillance.To our knowledge, this is the first study to report the application of LAMP to detect mcr-2 to mcr-5genes and the first time that multi-LAMP has been applied to detect mcrgenes.

Original languageEnglish
Pages (from-to)1877-1887
Number of pages11
JournalInfection and Drug Resistance
Volume12
DOIs
Publication statusPublished - 2 Jul 2019

Keywords

  • Colistin resistance
  • Enzyme digestion
  • Mcr genes
  • Multi-LAMP
  • Rapid detection

Fingerprint

Dive into the research topics of 'Multiplex loop-mediated isothermal amplification (multi-LAMP) assay for rapid detection of mcr-1 to mcr-5 in colistin-resistant bacteria'. Together they form a unique fingerprint.

Cite this