Skip to main navigation Skip to search Skip to main content

Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study

  • TBI Testing Team
  • , Han Thi Nguyen
  • , Luan Nguyen Quang Vo
  • , Andrew James Codlin
  • , Rachel Jeanette Forse
  • , Tom Wingfield
  • , Kristi Sidney Annerstedt
  • , Emily Lai Ho Maclean
  • , Jacob Creswell
  • , Beatrice Kirubi
  • , Hoa Binh Nguyen
  • , Luong Van Dinh
  • , Doan Thi Thuy Duong
  • , Lina Davies Forsman
  • Karolinska Institutet
  • Friends for International TB Relief
  • Friends for International TB Relief
  • World Health Organization
  • University of Sydney
  • Stop TB Partnership
  • Kenya Medical Research Institute
  • Viet Nam National Lung Hospital
  • National Lung Hospital
  • Hanoi University of Public Health
  • Karolinskal University Hospital

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Background
Tuberculosis (TB) infection is a driver of the global TB epidemic. Accurate, affordable, and simpler diagnostics are crucial for identifying people for preventive therapy. We evaluated the diagnostic performance of the STANDARD F TB-Feron FIA (TB-Feron), a near-point-of-care (POC) assay for detecting TB infection.

Methods
From June to December 2024, we conducted a cross-sectional study at the Vietnam National Lung Hospital, enrolling 352 participants, including 345 eligible participants: 95 with microbiologically confirmed pulmonary TB (Group 1), 200 household contacts of people with pulmonary TB (Group 2), and 50 with a recent history of a negative QFT-Plus result and no known TB exposure (Group 3). Participants were tested with TB-Feron and the reference standard, QuantiFERON TB Gold Plus (QFT-Plus). Results were compared for sensitivity and specificity (primary endpoints), with inter-test agreement (Cohen's κ) and reproducibility (Bland–Altman analysis) as secondary outcomes.

Results
Among 345 eligible participants, TB-Feron sensitivity was 88.4% (95% confidence interval [CI] 80.2–94.1) in Group 1, and specificity was 70.0% (55.4–82.1) in Group 3. In Group 2, positive and negative agreements with QFT-Plus were 89.2% (79.8–95.2%) and 75.4% (66.9–82.6), respectively, with inter-test agreement of 80.5% (Cohen's κ=0.6069, P < .0001). Intra-test reproducibility showed no significant differences in IFN-γ levels (mean difference = 2.08 IU/mL, 95% CI −1.28 to 5.44, P = .206).

Conclusions
With high sensitivity, the TB-Feron assay is a potential near-POC alternative to the QFT-Plus assay for diagnosing TB infection, but requires consideration of its suboptimal specificity.
Original languageEnglish
Article numberciaf561
Pages (from-to)e996-e1004
Number of pages10
JournalClinical Infectious Diseases
Volume82
Issue number5
Early online date26 Nov 2025
DOIs
Publication statusPublished - 26 Nov 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • fluorescent immunoassay
  • interferon-gamma release assays
  • point of care
  • QuantiFERON-TB Gold Plus
  • TB

Fingerprint

Dive into the research topics of 'Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study'. Together they form a unique fingerprint.

Cite this